Education · shoulder

Reverse Shoulder Arthroplasty Info In-depth Evidence Consent

Reviewed by Dr Kieran Hirpara, Specialist Orthopaedic Surgeon Last reviewed

Why this operation has been suggested

Dr Kieran Hirpara, an upper-limb surgeon at Mater Private Hospital Rockhampton, starts with the least invasive options that suit your condition. Patients are generally referred to our clinic by their GP; if a physiotherapist has suggested you see us, you will still need a referral from your GP in order to be eligible for the Medicare rebate. A clinic assessment establishes the diagnosis. For long-standing problems we usually try non-operative care first. We consider surgery when that has not given enough improvement.

This procedure replaces the shoulder joint to restore function when the rotator cuff is damaged. It is often recommended for complex fractures or arthritis where other treatments have failed. The operation aims to provide pain relief and stability. Revision surgery shows an implant survival rate of 85% at ten years. You can expect maximum improvement at one year.

Before the operation

Please fast for seven hours before your surgery. We ask for this specific window so your procedure can start early if the list runs ahead. Please arrange for someone to drive you home and stay with you afterward. Wear comfortable, loose-fitting clothing to your appointment. Bring a complete list of all medications you are currently taking. Your surgeon will review these with you and advise which ones to stop before the operation. Imaging such as X-rays or scans helps us plan your care. If you have other medical conditions, you may need blood tests or a review with the anaesthetist. Most patients do not require these unless specifically indicated.

On the day

You present to the hospital's surgical admissions unit for check-in and preparation. You meet the anaesthetist, who explains your care plan. This operation is done under general anaesthetic combined with a regional nerve block. You will be fully asleep for the operation, and the block — an injection that numbs the nerves supplying the arm before you wake up — provides pain relief for the first 12 to 24 hours after surgery. The anaesthetist will meet you before the operation and talk you through both parts.

You are then taken into the operating theatre for your surgery. Once the procedure is complete, you wake up in the recovery area. Nurses monitor you closely while the anaesthetic wears off and your vital signs stabilize. Once you are stable, you either go to the ward or go home, depending on the procedure and your recovery. We ensure you are comfortable and ready for the next step in your healing journey.

What the operation involves

Your surgeon makes a single cut over the shoulder area to access the joint. The worn-out surfaces of the ball and socket are removed. Your surgeon then replaces them with a reverse joint replacement. This device uses metal and plastic parts arranged in a specific way. This design creates a stable pivot point. It allows the large shoulder muscle (the deltoid) to lift your arm, even if the rotator cuff tendons are damaged or missing.

If you are having this operation for a fracture, your surgeon may also repair broken bone pieces. These pieces are held in place with small implants to help them heal correctly. Proper positioning of these bone fragments is important for restoring full movement later.

Once the new joint is in place, your surgeon closes the cut. A fine self-adhesive mesh is laid over the wound first to hold the skin edges together. A liquid skin adhesive is then painted over the mesh. This sets to seal the area. The dressing stays on for roughly one to two weeks and then lifts and peels away by itself. There is nothing to be taken out.

After the operation

You will wake up in the recovery ward with your arm in a simple sling for comfort. Most patients stay one night in hospital after this operation, though some are able to go home the same day. We will manage your pain with medication and care for your wound with dressings. You must have someone stay with you for the first 24 hours. Your arm rests in the sling, which you remove only for exercises and washing. We do not use hinged braces or abduction pillows. You must not drive while in a sling. You can drive again once your surgeon clears you, typically at the six-week review. See Driving after upper-limb surgery for details.

Recovery

You can expect some swelling and discomfort in the first few days. This is normal. Your surgeon will guide you on pain relief. Most people find their pain drops significantly after the first two weeks. You will wear a simple sling for comfort. It comes off for exercises and washing. We do not use hinged braces or abduction pillows.

Your physiotherapist will guide your rehabilitation. Early, active movement is safe and effective. You may start self-directed home therapy if it suits you. This shows similar results to supervised sessions. Your arm rests in the sling until you are ready to move. Gentle exercises begin as soon as your surgeon clears you.

You will notice steady gains in movement. Many people feel much better within two weeks. You will work towards full function over the next year. Your timeline may differ; your surgeon and physio will guide you. You can return to driving once your surgeon clears you, typically at the six-week review. See our guide on Driving after upper-limb surgery.

What can go wrong

Most patients do well, but problems can occasionally happen. Your surgeon and the team monitor you closely to spot any issue early.

If you have had previous shoulder surgery, your risk of needing another operation is higher than if this is your first procedure. However, if your previous surgery was a standard joint replacement that failed, the results of this revision are often similar to a primary operation.

Loosening of the shoulder blade component can happen over time. You might notice increased pain or a feeling of instability where the shoulder feels like it is slipping or giving way. If you feel sudden instability or increasing pain, contact the clinic for an assessment.

Wound healing issues are more likely if you need blood-thinning medication after surgery. You may see redness spreading from the cut, drainage that does not stop, or increased tenderness. If you notice signs of infection or poor healing, call the clinic promptly so we can check the wound.

Fractures of the upper arm bone near the shoulder are more common when revising a previous replacement. You might feel a sudden pop or sharp pain during movement, followed by significant swelling and bruising. If you experience sudden severe pain or inability to move the shoulder, seek urgent medical attention.

Younger patients may experience instability, where the joint feels loose or slips out of place. This can feel like a clicking sensation or a fear that the shoulder will dislocate. If you feel recurrent instability, bring it up at your next review so we can adjust your care plan.

Infection is a risk, but this procedure can still be successful even if the previous joint was infected. Signs include persistent fever, chills, or warmth around the shoulder. If you suspect an infection, contact the clinic immediately for evaluation.

The complications table on this page lists typical rates if you want the specifics.

When to call us

Call us if you develop a fever, increasing wound redness, or discharge. Go to emergency if you experience sudden severe pain, calf swelling, shortness of breath, loss of sensation, or inability to move your limb. These signs may indicate infection, blood clots, or fracture. We need to assess you promptly to protect your recovery and ensure your safety during the healing process.

Advanced reading: the deeper science (optional)

This section goes further than you need for your own treatment decisions. Reverse shoulder replacement is worth the extra reading because it is the operation that solved a problem previously thought unsolvable — a shoulder with no working rotator cuff — and because its characteristic complication is one most patients have never heard of.

Why reversing the joint works

A normal shoulder is a ball on the arm and a socket on the shoulder blade, and it depends on the rotator cuff to hold the ball centred while the deltoid lifts. Where the cuff is gone, a conventional replacement has nothing to stabilise it and the ball simply rides upwards.

The reverse design swaps them: the ball is fixed to the shoulder blade and the socket to the arm. That moves the centre of rotation inwards and downwards, which lengthens the deltoid's lever arm and lets it lift the arm on its own. It is a mechanical solution rather than a biological one — it does not repair anything, it makes the remaining muscle sufficient.

That also explains the pattern of what it restores. Overhead elevation usually returns well. Rotation depends on muscles the operation does not replace, so reaching behind the back often remains limited, and that should be part of the expectation set before surgery rather than a disappointment after it.

Where it has displaced older operations

For fractures, the shift has been decisive. Pooling 228,523 patients, reverse total shoulder arthroplasty gave better functional outcomes and complication rates than hemiarthroplasty, and a more favourable revision profile than plate fixation, in elderly patients with proximal humerus fractures [1].

An implant detail worth knowing, because it is often raised: comparing standard components with fracture-specific components in reverse replacement for these fractures across 436 patients found no significant differences in clinical outcomes or complication rates [2].

The complication to know about

The one that matters here is the acromial or scapular stress fracture — the bone above the joint cracking under the increased deltoid tension the design deliberately creates. It is the direct consequence of the mechanism that makes the operation work.

A meta-analysis identified the risk factors: patients who sustained these fractures were older with lower BMI, and other risks included osteoporosis, inflammatory arthritis, female sex and previous rotator cuff repair [3]. A separate review found the literature reports these fractures inconsistently — significant discrepancies in how they are defined, diagnosed and counted [4] — so quoted rates should be read with caution.

Set against that, the short-term picture is reassuring: overall rates of mortality and medical and surgical complications are low in the first 90 days, with only 6% of patients requiring readmission [5].

Two things the evidence does not support

That the subscapularis must be repaired. Across 267 patients, there were no differences in abduction, internal rotation or external rotation strength after reverse replacement with or without subscapularis repair, though the authors note the literature on strength outcomes is limited [6].

That the indication does not affect the result. It does. At two or more years, Constant scores were significantly higher in patients having reverse replacement for primary osteoarthritis with an intact cuff than for primary osteoarthritis with cuff tears or for secondary osteoarthritis [7]. The same operation gives different results depending on why you needed it — which is worth knowing when you are quoted an average.


References for the advanced reading
  1. Mekhail J, Mullan R, Cross JL, Jahagirdar O, Luo X, Salameh M. Outcomes of reverse total shoulder arthroplasty vs. other surgical fixation methods for proximal humerus fractures: a systematic review and meta-analysis. JSES Rev Rep Tech. 2026;6(2):100644.
  2. Apivatgaroon A, Kongmalai T, Kongmalai P. Standard compared with fracture-specific components in reverse shoulder arthroplasty for proximal humeral fractures: a systematic review and meta-analysis. Bone Joint J. 2025;107-B(9):931-41.
  3. Elmenawi KA, Sperling JW, Sanchez-Sotelo J, Barlow JD. Risk factors for acromial and scapular fractures following reverse shoulder arthroplasty: a meta-analysis. JSES Rev Rep Tech. 2026;6(1):100578.
  4. Davie RA, Nathan K, Persaud SG, Oladeji LO, Taylor SA, Dines JS, et al. Inconsistent reporting of risk factors for acromial stress fractures following reverse total shoulder arthroplasty: a systematic review. J Shoulder Elbow Surg. 2025;34(11):e975-e984.
  5. Kent LM, Hurley ET, Davey MS, Klifto CS, Mullett H. Low complication rate following reverse total shoulder arthroplasty at 90-days follow-up: a systematic review. J ISAKOS. 2024;9(2):205-10.
  6. Preuss FR, Eble SK, Peebles AM, Osuna-Garcia A, Provencher CMT. Shoulder strength outcomes after reverse total shoulder arthroplasty: a systematic review. JSES Rev Rep Tech. 2022;2(2):131-4.
  7. Nové-Josserand L, Nerot C, Colotte P, Guery J, van Rooij F, Hibon A, et al. Reverse shoulder arthroplasty for primary glenohumeral osteoarthritis: significantly different characteristics and outcomes in shoulders with intact vs. torn rotator cuff. J Shoulder Elbow Surg. 2024;33(4):850-62.
Evidence & references

This is the clinical evidence summary written for health professionals. It is technical, and it lists the research this page was built from. You do not need to read it to understand your treatment or to make a decision about it.

Anatomy & Pathophysiology

  • Periprosthetic scapular fractures about reverse shoulder arthroplasty are universally associated with stable glenoid implants [2].
  • Scapular fractures are unlikely to occur in the face of dislocation, glenosphere dissociation, or baseplate pullout at the bone–baseplate interface [2].
  • Periprosthetic scapular fractures can result in new glenohumeral instability due to a change in the orientation of the glenosphere and loss of deltoid tension [2].
  • The glenoid is suspended from the body of the scapula by the neck and fixed to the clavicle by the acromioclavicular and coracoclavicular ligaments [3].
  • As the face of the glenoid transitions into the neck, the glenoid vault narrows [3].
  • Optimal fixation for reverse shoulder arthroplasty involves implanting the central peg or screw within the glenoid vault in the axis of the body of the scapula without perforation [3].
  • Peripheral locking screws enhance implant stability to allow for bony ingrowth [3].
  • Optimal bony corridors for peripheral screws guide fixation within the lateral pillar of the scapula (inferior and posterior screws), the base of the coracoid (superior screw), and the scapular spine (anterior screw) [3].
  • The scapular spine is subcutaneous posteriorly and widens gradually as it transitions into the base of the acromion laterally [3].
  • The acromion curves anteriorly and meets the clavicle at the acromioclavicular joint and the coracoid via the coracoacromial ligament, which originates under the anterior margin of the acromion [3].
  • The suprascapular nerve arises from the C4–C5 nerve roots off of the supraclavicular brachial plexus at "Erb's point" [3].
  • The suprascapular nerve runs just medial to the base of the coracoid, under the transverse scapular ligament within the suprascapular notch, and gives off branches to the supraspinatus within 1 cm of the notch [3].
  • The suprascapular nerve continues through the supraspinatus fossa heading laterally and distally on the under surface of the supraspinatus [3].
  • The suprascapular nerve runs under the ill-defined spinoglenoid ligament around the lateral base of the scapula within the spinoglenoid notch before terminating in posterior capsular sensory branches and an infraspinatus motor branch within 1 cm of the lateral margin of the scapular spine [3].
  • Cadaver studies show the suprascapular nerve is present 29 mm (23 to 35 mm) from the superior rim of the glenoid at the suprascapular notch [3].
  • Cadaver studies show the suprascapular nerve is present 18 mm (14 to 24 mm) from the posterior rim at the spinoglenoid notch [3].
  • Injury to the suprascapular nerve can cause pain and denervation of the supraspinatus and infraspinatus [3].
  • The traditional Grammont reverse prosthesis features a glenoid component with an articulating portion shaped as a third of a sphere [4].
  • In the Grammont reverse prosthesis, the center of rotation is medial to the glenoid component–bone interface [4].
  • The humeral component in the Grammont reverse prosthesis is inset, resting almost completely inside the proximal humerus metaphysis [4].
  • The opening angle of the polyethylene in the Grammont reverse prosthesis is relatively horizontal at 155 degrees [4].
  • In the Grammont reverse prosthesis, the humerus is positioned more medially and more distally than preoperatively [4].
  • The humeral component in the Grammont reverse prosthesis is recommended to be implanted in more anteversion (0 to 10 degrees of retroversion) than conventional arthroplasty [4].
  • Subsequent reverse designs have modified features to place the center of rotation more lateral than the Grammont prosthesis [4].
  • Later reverse designs introduced an opening angle of 135 degrees for the humeral component [4].
  • Later designs introduced humeral components with an onlay humeral bearing, which lateralized the position of the humerus without changing the center of rotation of the arthroplasty [4].
  • Later designs selected a 145-degree opening angle for the bearing [4].
  • The RSA does not require the rotator cuff for function but is dependent on an intact deltoid neuromuscular unit [7].
  • The Grammont principles of RSA include that the prosthesis must be inherently stable and perfectly concentric [7].
  • The Grammont principles of RSA include that the weight-bearing part must be convex and the supported part concave (reversed) [7].
  • The Grammont principles of RSA include that the center of the sphere must be at or within the glenoid neck (medialized) [7].
  • The Grammont principles of RSA include that the center of rotation must be medialized and distalized [7].
  • The traditional Grammont style decreases shear forces seen by the glenoid and lowers baseplate failure by medializing the center of rotation [7].
  • The traditional Grammont style carries a risk of inferior scapular notching in adduction, which is associated with poorer results [7].
  • Distalization in RSA doubles the lever arm of the deltoid and optimizes the length–tension curve of its sarcomeres [7].
  • Distalization in RSA increases deltoid efficiency by 30% at the cost of rotational strength [7].
  • Lateralized glenosphere and lateralized humerus designs have gained popularity to improve the rotational profile, deltoid function, implant stability, and decrease impingement (scapular notching) [7].
  • Early reverse shoulder arthroplasty designs had a high failure rate due to the profound lever arm on the glenoid and baseplate bone [7].
  • Recent reverse shoulder arthroplasty designs have a better track record but result in increased forces seen by the scapula and acromion [7].
  • Postoperative periprosthetic scapular fractures occur at rates of 0.9% to 11.2% [7].
  • Periprosthetic scapular fractures are a unique complication of reverse shoulder arthroplasty that occurs more commonly than periprosthetic humeral fractures [7].
  • Female gender has been implicated as a risk factor for postoperative periprosthetic scapular fractures, accounting for up to 100% of some series [7].
  • Postoperative periprosthetic scapular fractures typically occur in patients aged 70 to 80 years [7].
  • One study of patients under age 65 undergoing reverse shoulder arthroplasty showed a 0% (0/67) postoperative periprosthetic scapular fracture rate [7].
  • Osteoporosis has been implicated as a risk factor for postoperative periprosthetic scapular fractures [7].
  • In one study, 75% (6/8) of acromial fractures occurred in osteoporotic hosts [7].
  • A study comparing 53 postoperative scapular spine fractures with 212 matched controls identified osteoporosis as a significant risk factor (30.8% fracture patients vs. 18.4% controls; OR 1.97; p < 0.05) [7].
  • Fatigue fractures of the scapula have been found to occur through already weakened acromia or those with preexisting lesions [7].
  • Acromial thinning and eventual fragmentation occur at the final stages of rotator cuff-tear arthropathy [7].

Clinical Presentation

  • Periprosthetic scapular fractures are universally associated with stable glenoid implants [2].
  • Scapular fractures are unlikely to occur in the presence of glenohumeral dislocation, glenosphere dissociation, or baseplate pullout at the bone–baseplate interface [2].
  • Periprosthetic scapular fractures can rarely result in new glenohumeral instability due to a change in glenosphere orientation and loss of deltoid tension [2].
  • A case of periprosthetic scapular fracture occurred 8 months after successful reverse shoulder arthroplasty for rotator cuff tear arthropathy [2].
  • Patients with periprosthetic scapular fractures may experience a profound loss of function following a fall despite substantial prior pain relief and function [2].
  • Periprosthetic scapular fractures can present as minimally displaced fractures involving the scapular neck and body, confirmed via CT scanning [2].
  • Diagnosis of periprosthetic fractures often requires a high index of suspicion due to subtle presentation [2].
  • Workup for periprosthetic fractures should begin with a complete history and examination [2].
  • History taking should elucidate the underlying diagnosis for the index surgery, subsequent surgeries, and any complications including infection [2].
  • The examiner must understand the patient's shoulder function and level of disability before surgery, after surgery, and at present [2].
  • The time course of functional changes should be documented during history taking [2].
  • New pain at the base of the acromion may be the only finding in cases of stress reaction [2].
  • Stress fractures can be more painful than when they propagate into displaced fractures [2].
  • Patients with periprosthetic scapular fractures typically present in their 8th decade of life [2].
  • Presentation is generally characterized by a sudden increase in pain or loss of function in an otherwise smooth postoperative course [2].
  • Periprosthetic scapular fractures generally occur within 1 year but up to 2 years from surgery [2].
  • Patients who develop periprosthetic scapular fractures initially outperform those who do not [2].
  • Risk factors for periprosthetic scapular fractures include a history of steroid use, osteoporosis, subacromial decompression, or rotator cuff tear arthropathy [2].
  • Previous operative reports, clinic notes, and imaging can help identify risk factors such as previous shoulder surgeries or history of radiation [2].
  • Deformity on physical examination is concerning for dislocation, hematoma, or displaced fracture [2].
  • Erythema or incisional dehiscence on physical examination is concerning for infection [2].
  • Tenderness along the acromion or scapular spine raises suspicion for fracture [2].
  • A complete neurovascular examination is part of the physical assessment for periprosthetic fractures [2].
  • Active and passive motion should be assessed during the physical examination [2].
  • Fractures can result in motion limited by pain, new weakness, or loss of function [2].
  • Sudden loss of function or increase in pain is consistent with both scapular fracture and infection [2].

Investigations

  • Diagnosis of periprosthetic scapular fractures often requires a high index of suspicion as identification can be subtle [2].
  • Workup for periprosthetic scapular fractures should begin with a complete history and examination [2].
  • New pain at the base of the acromion may be the only finding in a stress reaction and should raise suspicion for further imaging or rest [2].
  • Stress fractures can be more painful than when they propagate into a displaced fracture [2].
  • Patients with periprosthetic scapular fractures typically present around their 8th decade of life after a sudden increase in pain or loss of function [2].
  • Physical examination for periprosthetic scapular fractures should include inspection for deformity, erythema, or incisional dehiscence [2].
  • Tenderness along the acromion or scapular spine raises suspicion for fracture and should be confirmed with imaging [2].
  • A complete neurovascular examination and assessment of active and passive motion are required during the physical examination for periprosthetic scapular fractures [2].
  • The glenoid vault narrows as the face of the glenoid transitions into the neck [3].
  • Peripheral locking screws enhance the ability to obtain implant stability long enough for bony ingrowth [3].
  • Optimal bony corridors for peripheral screws guide fixation within the lateral pillar of the scapula (inferior and posterior screws), the base of the coracoid (superior screw), and scapular spine (anterior screw) [3].
  • The suprascapular nerve runs just medial to the base of the coracoid, under the transverse scapular ligament within the suprascapular notch [3].
  • The suprascapular nerve gives off branches to the supraspinatus within 1 cm of the notch [3].
  • The suprascapular nerve runs under the spinoglenoid ligament around the lateral base of the scapula within the spinoglenoid notch before terminating in posterior capsular sensory branches and an infraspinatus motor branch [3].
  • It is recommended to limit superior screw length to ≤25 mm and posterior screws to ≤15 mm when possible to reduce the risk of suprascapular nerve injury [3].
  • The suprascapular nerve can be injured by the fracture itself or become encased in callus [3].
  • Careful assessment of preoperative radiographs and CT with three-dimensional reconstruction is extremely useful for preoperative planning in reverse shoulder arthroplasty for fracture [5].
  • Preoperative planning goals include understanding the fracture pattern and anticipating the ideal height of stem implantation [5].
  • Radiographs of both humeri with magnifier markers may be used to understand where the stem should be positioned in reference to the fracture line on the humeral shaft [5].
  • The glenoid should be assessed in radiographs and CT to plan for component positioning, version, inclination, and rotation, as well as anticipated screw length [5].
  • Rarely, there may be associated fractures of the rim of the glenoid in anterior or posterior fracture-dislocations [5].
  • If a fractured glenoid rim is large enough to interfere with the stability of the glenoid baseplate, fixation with small fragment screws may be performed [5].
  • Reverse shoulder arthroplasty is best performed in the beach chair position, specifically the "barber chair" position with the trunk at approximately 70 degrees [5].
  • The deltopectoral approach is preferred for reverse arthroplasty for fracture due to familiarity, easier placement of the glenoid component low and with an inferior tilt, and extensibility of exposure [5].
  • Management and reduction of the greater tuberosity is easier from a superior deltoid-splitting approach [5].
  • Radiographic identification of periprosthetic scapular fractures can be subtle [10].
  • Plane radiographs for periprosthetic scapular fractures should include AP, scapular Y, and axillary views [10].
  • Radiographs should be compared with preoperative and initial postoperative images to identify subtle changes [10].
  • Preoperative images can identify a missed os acromiale or insufficiency fracture which can displace after deltoid tensioning in reverse shoulder arthroplasty [10].
  • Implant dissociation or loosening presents with a change in implant position on serial radiographs [10].
  • Progressive downsloping of the acromion relative to the scapular spine indicates a displaced acromial fracture [10].
  • Narrowing of the acromial–tuberosity interval indicates a displaced acromial fracture [10].
  • The scapular Y view identifies displaced scapular spine or body fractures [10].
  • The axillary view is helpful for identifying the location of the fracture, especially at the acromial base [10].
  • Plain radiographs can miss more subtle fractures [10].
  • Levy et al. found that plain radiographs were unreliable at detecting fracture (k = 0.05) or fracture union (k = 0.05) [10].
  • In Otto's series, 32.1% (17/53) of fractures presented with pain and negative plain films [10].
  • Independent reviewers were able to accurately diagnose 78.8% of periprosthetic scapular fractures with good inter-rater reliability (k = 0.782) and excellent intra-rater reliability (k = 0.862) [10].
  • Patients with fractures had greater changes in acromial–tuberosity distance (p < 0.001) and acromial tilt (p < 0.001) from initial postoperative radiographs to final images [10].
  • It is recommended to routinely evaluate acromial–tuberosity distance and acromial tilt to improve detection of periprosthetic scapular fractures [10].
  • New pain along the scapula in the setting of normal radiographs should trigger a CT scan [10].
  • In Levy et al.'s series, 39% (7/18) of fractures were associated with negative plain films and required a CT scan to diagnose nondisplaced fractures [10].
  • A negative CT scan may occur in the setting of a stress reaction which may be better elicited on a bone scan [10].

Treatment

  • Reverse shoulder arthroplasty is currently the replacement procedure of choice when arthroplasty is considered for proximal humeral fractures [4].
  • The rate of utilization of reverse shoulder arthroplasty for proximal humeral fractures is increasing [4].
  • Reverse shoulder arthroplasty was developed for the surgical management of cuff tear arthropathy [4].
  • The semiconstrained nature of the reverse prosthesis provides a stable fulcrum that allows the deltoid to elevate the shoulder even in the absence of a functional rotator cuff [4].
  • Tuberosity and rotator cuff-related complications are the main reason for poor functional outcomes when a humeral head replacement is implanted for management of a proximal humeral fracture [4].
  • In the Grammont reverse prosthesis, the articulating portion of the glenoid component has the shape of a third of a sphere [4].
  • The intention of medializing the center of rotation in the Grammont design is to decrease shear stress and provide compressive stress to decrease the chances of glenoid loosening [4].
  • In the Grammont reverse prosthesis, the humeral component is inset, resting almost completely inside the proximal humerus metaphysis [4].
  • Once articulated in a Grammont reverse prosthesis, the humerus is positioned more medially and more distally than preoperatively [4].
  • A more horizontal opening angle was selected in the Grammont design to decrease the chances of dislocation [4].
  • Subsequent reverse designs have modified features such as using a larger portion of a sphere and placing the center of rotation more lateral than the Grammont prosthesis [4].
  • Selected later designs use a 145-degree opening angle for the bearing [4].
  • There is very little published on reverse arthroplasty biomechanics in the setting of a proximal humeral fracture [4].
  • Some surgeons initially elected to implant a reverse arthroplasty in proximal humeral fractures without repair or with excision of the greater and/or lesser tuberosity [4].
  • Controversy remains regarding the impact of tuberosity healing on the outcome of reverse arthroplasty for fracture [4].
  • Many believe that healing of at least the greater tuberosity in good position provides a higher chance of restoration of active external rotation [4].
  • Active external rotation is very important for the overall functional outcome [4].
  • In the treatment of proximal humeral nonunion, not performing a tuberosity repair at the time of reverse arthroplasty has been correlated with a higher rate of dislocation [4].
  • Technical principles for reverse arthroplasty in cuff tear arthropathy may need to be modified to enhance tuberosity healing, such as avoiding translating the humeral shaft too lateral or too distal [4].
  • The tuberosities should overlap a few millimeters with the shaft to facilitate healing [4].
  • Use of a stem with fracture-dedicated features, including a proximal ingrowth surface, small cross section, and holes for suture fixation, may be beneficial [4].
  • Shoulder arthroplasty is considered for proximal humeral nonunion in the presence of severe cavitation and bone loss at the humeral head and metaphysis or collapse and degenerative change of the humeral articular surface [6].
  • Severe tuberosity malunion in a proximal humeral nonunion is more reliably compensated for with reverse arthroplasty than with osteotomy and internal fixation [6].
  • Hemiarthroplasty is less commonly considered than reverse arthroplasty for proximal humeral nonunion [6].
  • The functional outcome of hemiarthroplasty for nonunion is particularly concerning when tuberosity osteotomies need to be added [6].
  • Most studies reporting on hemiarthroplasty for nonunion suggest the procedure may be effective in reducing or eliminating pain [6].
  • Hemiarthroplasty for nonunion is associated with a high rate of complications that often require further surgery and disappointing functional recovery [6].
  • Reverse shoulder arthroplasty may improve shoulder function in patients with nonunions associated with severe tuberosity malunions [6].

Complications

  • Scapular notching is a specific complication of reverse shoulder arthroplasty that requires avoidance strategies [1, 26].
  • The impact of scapular notching on clinical outcomes after reverse shoulder arthroplasty has been analyzed in a cohort of 476 shoulders [26].
  • Subscapularis tendon integrity after reverse shoulder arthroplasty impacts shoulder function [1].
  • Comparison of reverse total shoulder arthroplasty outcomes with and without subscapularis repair has been performed [1].
  • Sonographic assessment of the subscapularis after reverse shoulder arthroplasty evaluates the impact of tendon integrity on shoulder function [1].
  • Optimal screw placement for base plate fixation in reverse total shoulder arthroplasty is a critical technical consideration [1].
  • The effect of component positioning on intrinsic stability of the reverse shoulder arthroplasty has been studied [1].
  • Humeral component lateralization in reverse shoulder arthroplasty affects rotator cuff torque in a cadaver model [1].
  • Humeral version in reverse shoulder arthroplasty affects impingement in activities of daily living [1].
  • The clinical and radiographic impact of center of rotation in reverse shoulder arthroplasty has been reviewed systematically [1].
  • Glenoid bone grafting is utilized in primary reverse total shoulder arthroplasty for glenoid deficiency [1].
  • Structural bone grafting is used for glenoid deficiency in primary total shoulder arthroplasty [1].
  • Comparison of radiographic and clinical outcomes of revision reverse total shoulder arthroplasty with structural versus nonstructural bone graft has been conducted [1].
  • Posteriorly augmented glenoid components are used in anatomic total shoulder arthroplasty for primary osteoarthritis with posterior glenoid bone loss [1].
  • Reverse total shoulder arthroplasty is indicated for massive irreparable rotator cuff tears in patients younger than 65 years old [1].
  • Reverse total shoulder arthroplasty is indicated for massive, irreparable rotator cuff tears before the age of 60 years [1].
  • Reverse total shoulder arthroplasty is indicated for the treatment of irreparable rotator cuff tear without glenohumeral arthritis [1].
  • Reverse total shoulder arthroplasty improves function in cuff tear arthropathy [1].
  • Functional outcomes of reverse shoulder arthroplasty compared with hemiarthroplasty for acute proximal humeral fractures have been evaluated [1].
  • Comparison of hemiarthroplasty and reverse shoulder arthroplasty for the treatment of fractures in elderly patients has been performed [1].
  • Reverse total shoulder arthroplasty versus hemiarthroplasty for proximal humeral fractures has been the subject of a systematic review [1].
  • Three- and four-part displaced proximal humeral fractures in patients older than 70 years have been treated with reverse shoulder arthroplasty versus nonsurgical treatment [1].
  • Short-stem uncemented primary reverse shoulder arthroplasty has demonstrated clinical and radiological outcomes [1].
  • Reverse total shoulder arthroplasty in patients with rheumatoid arthritis has been studied [1].
  • Short-term results after reverse shoulder arthroplasty in patients with rheumatoid arthritis and irreparable rotator cuff tear have been reported [1].
  • Reverse total shoulder arthroplasty for primary glenohumeral osteoarthritis in patients with a biconcave glenoid has been evaluated [1].
  • Long-term outcomes of reverse total shoulder arthroplasty have been followed up in a previous study [1].

References

[1] Campbell S Operative Orthopaedics 4 Volume Set. RECONSTRUCTIVE PROCEDURES OF THE SHOULDER AND ELBOW IN ADULTS > REVERSE SHOULDER ARTHROPLASTY.

[2] Rockwood And Green S Fractures In Adults. 29: Principles of Nonunion and Bone Defect Treatment > Injuries Associated with Periprosthetic Scapular Fractures About Reverse Shoulder Arthroplasty.

[3] Rockwood And Green S Fractures In Adults. 29: Principles of Nonunion and Bone Defect Treatment > Pathoanatomy and Applied Anatomy Related to Periprosthetic Scapular Fractures About Reverse Shoulder Arthroplasty.

[4] Rockwood And Green S Fractures In Adults. 29: Principles of Nonunion and Bone Defect Treatment > Reverse Shoulder Arthroplasty.

[5] Rockwood And Green S Fractures In Adults. 29: Principles of Nonunion and Bone Defect Treatment > Preoperative Planning > Reverse Shoulder Arthroplasty for Fracture: Preoperative Planning Checklist.

[6] Rockwood And Green S Fractures In Adults. 29: Principles of Nonunion and Bone Defect Treatment > Reverse Shoulder Arthroplasty and Hemiarthroplasty.

[7] Rockwood And Green S Fractures In Adults. 29: Principles of Nonunion and Bone Defect Treatment > Periprosthetic Scapular Fractures About Reverse Shoulder Arthroplasty.

[10] Rockwood And Green S Fractures In Adults. 29: Principles of Nonunion and Bone Defect Treatment > Imaging and Other Diagnostic Studies on Periprosthetic Scapular Fractures About Reverse Shoulder Arthroplasty.